3M™ VFlex™ 1804 Health Care N95 Respirator & Surgical Mask, Flat-Fold, 80 mmHg Fluid-Resistant, BX/50 or CS/400
3M™ VFlex™ 1804 Health Care N95 Respirators and Surgical Masks feature a NIOSH-approved N95 design with ASTM F1862 fluid resistance at 80 mmHg, V-shaped pleats, adjustable nose clips, and dual elastic headbands. FDA-cleared for use as surgical masks, these disposable respirators provide particulate filtration and a flexible flat-fold fit. White, non-sterile, standard adult size. Available by Box (50 respirators) or Case (8 boxes / 400 respirators).
Customize
Product Details
The 3M™ VFlex™ Health Care Particulate Respirator and Surgical Mask (MPN 1804) is a NIOSH-approved N95 filtering facepiece respirator designed for professional healthcare environments requiring respiratory protection and fluid resistance. It combines particulate filtration performance with FDA-cleared surgical-mask functionality for use in appropriate clinical settings.
The distinctive V-shaped pleats expand to create a spacious fit and flex with mouth movement during speaking. The flat-fold construction allows convenient storage before use, while proprietary 3M Advanced Electrostatic Media helps capture certain airborne particles while supporting breathing comfort.
A flexible adjustable nose clip, dual elastic headbands, and positioning tabs help the wearer achieve proper positioning and a secure facial seal. The standard adult-size design accommodates a range of facial shapes when appropriately selected and fit-tested.
The VFlex™ 1804 provides a minimum 95% filtration efficiency against qualifying non-oil-based particles under NIOSH N95 requirements. It is fluid-resistant to 80 mmHg under ASTM F1862 testing and offers greater than 99% bacterial filtration efficiency under ASTM F2101.
This respirator is white, non-sterile, disposable, and not made with natural rubber latex. It is intended for professional healthcare applications, including surgical and other clinical environments where the product's specifications and applicable respiratory-protection requirements are appropriate.
Ordering & Packaging: Available by Box (BX/50EA) or Case (CS/8BX/50EA). Each case contains eight manufacturer boxes of 50 respirators, totaling 400 disposable 3M™ VFlex™ 1804 surgical N95 respirators. Individual respirators are not sold separately.
Key Features
| Feature | Detail | Feature | Detail |
|---|---|---|---|
| Respirator Classification | NIOSH N95 | Surgical Mask Status | FDA-Cleared |
| NIOSH Approval | TC-84A-7789 | Fluid Resistance | ASTM F1862, 80 mmHg |
| Particulate Filtration | At Least 95% | Bacterial Filtration | Greater Than 99% |
| Respirator Design | V-Shaped Pleated Flat-Fold | Exhalation Valve | None |
| Filter Technology | Advanced Electrostatic Media | Nose Adjustment | Adjustable Nose Clip |
| Fastening Style | Dual Elastic Headbands | Positioning Feature | Integrated Side Tabs |
| Size | Standard Adult | Product Color | White |
| Sterility | Non-Sterile | Intended Use | Disposable / Single Use |
| Natural Rubber Latex | Not Made with Natural Rubber Latex | Ordering Options | Box or Case |
Specifications
| Specification | Detail | Specification | Detail |
|---|---|---|---|
| Brand | 3M™ VFlex™ | Manufacturer | 3M Company |
| MPN | 1804 | McKesson Item # | 1110513 |
| 3M Product ID | 7100145153 | Manufacturer UPC/GTIN | 50051131275923 |
| Product Type | Health Care N95 Respirator / Surgical Mask | Respirator Style | Flat-Fold |
| Respirator Classification | N95 | NIOSH Approval | TC-84A-7789 |
| Particle Filtration Efficiency | At Least 95% | Bacterial Filtration Efficiency | Greater Than 99% |
| Fluid Resistance | 80 mmHg | Fluid Test Standard | ASTM F1862 |
| BFE Test Standard | ASTM F2101 | Exhalation Valve | No |
| Filter Material | Polypropylene | Coverweb Material | Polypropylene |
| Headband Material | Polyisoprene | Headband Attachment | Steel Staples |
| Nose Clip | Aluminum | Nose Foam | None |
| Size | Standard / One Size Fits Most | Intended User | Adult |
| Color | White | Sterility | Non-Sterile |
| Usage | Disposable / Single Use | Natural Rubber Latex | Not Made with Natural Rubber Latex |
| Approximate Unit Weight | 0.40 oz / 11.34 g | Country of Origin | USA with Globally Sourced Materials |
| FDA 510(k) | K171116 | FDA Product Code | MSH |
| Box Configuration | BX/50EA | Case Configuration | CS/8BX/50EA |
| Respirators per Box | 50 | Respirators per Case | 400 |
| Ordering Units | BX, CS | UNSPSC | 46182010 |
| BAA Compliant | No | TAA Compliant | No |
Warnings
Intended for professional healthcare applications in accordance with the manufacturer's instructions.
Respirators must be properly selected, fit-tested, and worn to provide the intended protection.
Workplaces requiring respiratory protection must comply with applicable OSHA respiratory-protection requirements, including 29 CFR 1910.134.
N95 filtration is intended for certain non-oil-based particulate contaminants. The respirator does not protect against gases, vapors, or oxygen-deficient atmospheres.
Do not use in industrial settings or for applications outside the manufacturer's specified intended uses.
A proper facial seal is essential. Facial hair or other conditions that interfere with the seal may reduce protection.
Inspect the respirator, nose clip, and elastic headbands before use. Do not use damaged, contaminated, or expired products.
Non-sterile, single-use product. Do not wash or alter. Discard after use in surgical procedures and follow applicable infection-control guidance.
Replace the respirator if it becomes damaged, contaminated, or difficult to breathe through.
Store in original packaging between -4°F and 86°F (-20°C to 30°C), at relative humidity not exceeding 80%.
Consult the manufacturer's user instructions for proper donning, seal checking, use limitations, and disposal. Misuse may result in illness or death.