Assure Titanium Blood Glucose Control Solution Level 2 & 3 – PK is designed for quality-control testing with the Assure Titanium professional blood glucose monitoring system. The control solutions provide known glucose concentrations that allow healthcare professionals to verify that the meter and compatible test strips are working together properly before patient testing.
The pack contains both Level 2 and Level 3 control solutions, supporting the Assure Titanium system's routine quality-control workflow. Control testing can be performed when using the meter for the first time, opening a new vial or lot of test strips, checking system performance, troubleshooting unexpected results, or completing the system's required QC procedure.
Key Features
| Level 2 Control | Level 3 Control | System Verification |
| Provides a normal-range glucose control | Provides a high-range glucose control | Helps verify meter and test-strip performance |
| Assure Titanium Compatible | Routine QC Testing | Two-Level Pack |
| Specifically designed for the Assure Titanium monitoring system | Supports professional point-of-care quality-control procedures | Includes both required control levels in one package |
| QC Lockout Support | No Blood Required | Professional Workflow |
| Supports the system's 24-hour QC requirements | Simulates a glucose sample for system verification | Designed for recurring professional testing environments |
Specifications
| Attribute | Details | Attribute | Details |
| Brand | Assure Titanium | Manufacturer | ARKRAY USA |
| MPN | 510006 | Product Type | Blood Glucose Control Solution |
| Application | Glucose Meter Quality Control | For Use With | Assure Titanium Blood Glucose Monitoring System |
| Included Levels | Level 2 and Level 3 | Quantity | 2 Control Solutions per Pack |
| Level 2 Target | Approximately 130 mg/dL | Level 3 Target | Approximately 360 mg/dL |
| Test Type | Quality Control | Patient Sample | Not Required |
| System Recognition | Control Results Automatically Identified by Meter | QC Frequency | Per Applicable Assure Titanium QC Protocol |
| Opened Solution Use Period | Up to 180 Days | Storage Temperature | 36–86°F / 2–30°C |
| Operating Temperature | 46–86°F / 8–30°C | Product Packaging | PK |
| Minimum Selling Unit | PK | UNSPSC | 41116107 |
| BAA Compliant | No | TAA Compliant | No |
Warnings
| Control Testing Only | Not for Patient Testing | Compatible System Only |
| Use only for blood glucose monitoring system quality control | Do not apply or administer the solution to a patient | Use with the Assure Titanium system and compatible test strips |
| Check Control Range | Replace Cap After Use | Expiration Dating |
| Compare results with the control range printed on the applicable test-strip vial | Close bottles securely after dispensing control solution | Do not use beyond the labeled expiration or permitted opened-use period |
| Out-of-Range Results | Proper Storage | Follow System Instructions |
| Do not perform patient testing if repeated control results remain outside the acceptable range | Store within the specified temperature range | Follow the Assure Titanium meter, test-strip, and control-solution instructions for QC procedures |