BD Alaris™ IV Pump Infusion Set, 3 SmartSite™ Ports, 0.2 Micron Filter, 117", (20/Case)
BD Alaris™ IV Pump Infusion Set (2432-0007) is a sterile fluid-path administration set designed for compatible BD Alaris™ Pump Modules. Featuring approximately 117-inch standardbore tubing, three SmartSite™ needle-free Y-sites, a 0.2 micron inline filter, and a 20 drops/mL drip factor, this set supports controlled intravenous fluid and medication administration. The configuration includes a backcheck valve, roller and slide clamps, and a two-piece male Luer lock connector.
Ordering: Sold by Case Only (CS/20EA). Each case contains 20 single-use infusion sets. Minimum selling/purchasing unit: Case. Individual infusion sets are not sold separately.
Customize
Product Details
BD Alaris™ IV Pump Infusion Set is designed for use with compatible BD Alaris™ Pump Modules to support intravenous fluid and medication administration in professional healthcare environments. This standardbore administration set combines approximately 117-inch tubing with a 20 drops/mL drip factor and a 0.2 micron inline filter for fluid-path filtration during infusion therapy.
The set includes three SmartSite™ needle-free Y-site valves located approximately 6, 18, and 86 inches from the two-piece male Luer lock connector. This configuration provides multiple access points along the administration line, including one above and two below the pumping segment.
An integrated backcheck valve, roller clamp, and slide clamp provide components for flow management within the administration set. The 0.2 micron low-protein-binding inline filter offers a filtration option for compatible infusion therapies. The set has an approximate priming volume of 28 mL, and its fluid path is supplied sterile.
Designed for use in hospitals, critical care units, medical-surgical departments, outpatient infusion facilities, and other clinical settings, the BD Alaris™ 2432-0007 set provides a specialized configuration for healthcare professionals using compatible infusion systems.
Ordering & Packaging: Sold by Case Only (CS/20EA). Each case contains 20 single-use infusion sets. Minimum ordering unit: 1 Case. Individual sets are not sold separately.
Key Features
| Feature | Detail | Feature | Detail |
|---|---|---|---|
| Pump Compatibility | BD Alaris™ Pump Module | Tubing Length | Approx. 117 Inches |
| Filter | 0.2 Micron Inline | Tubing Type | Standardbore |
| Drip Factor | 20 Drops/mL | Priming Volume | Approx. 28 mL |
| Y-Site Ports | 3 SmartSite™ | Port Design | Needle-Free |
| Valve | 1 Backcheck | Clamps | Roller & Slide |
| Connection | Male Luer Lock | Fluid Path | Sterile |
| Usage | Single Use | Application | IV Infusion Therapy |
| Packaging | 20 EA/CS | Minimum Unit | CS |
| Ordering Units | Case Only | Sets Per Case | 20 |
Specifications
| Specification | Detail | Specification | Detail |
|---|---|---|---|
| Brand | BD Alaris™ | Manufacturer | Becton, Dickinson and Company |
| MPN | 2432-0007 | Product Type | IV Pump Infusion Set |
| Product Line | Alaris™ LVP | Administration Method | Pump |
| Tubing Length | 117 Inches (Approx.) | Tubing Bore | Standard |
| Filter Size | 0.2 Micron | Filter Type | Low-Protein-Binding |
| Drip Rate | 20 Drops/mL | Priming Volume | 28 mL |
| Number of Ports | 3 | Port Type | SmartSite™ Y-Site |
| Valve Configuration | 1 Backcheck Valve | Flow Control | Roller & Slide Clamps |
| Connection Type | 2-Piece Male Luer Lock | Sterility | Fluid Path Sterile |
| Device Classification | Prescription Use (Rx) | Usage | Single Use |
| GTIN Each | 10885403232329 | GTIN Case | 50885403232327 |
| Case Packaging | CS/20EA | Minimum Selling Unit | Case |
| Available Units | CS Only | Country of Manufacture | Mexico |
Warnings
PRESCRIPTION USE (Rx) — FOR PROFESSIONAL HEALTHCARE USE.
For use with compatible BD Alaris™ infusion pump systems. Verify compatibility with the specific pump module and current manufacturer instructions before use.
Single-use medical device. Do not reuse or reprocess.
The fluid path is supplied sterile. Inspect the original packaging before use and do not use if sterility or package integrity is compromised.
Confirm the expiration date and lot information before use.
Follow the manufacturer's Instructions for Use for proper installation, priming, pump operation, and infusion monitoring.
Verify the suitability of the 0.2 micron filter for the prescribed medication or solution and applicable clinical protocol.
Use appropriate aseptic technique when handling the administration set and accessing needle-free ports.
Dispose of used infusion sets according to applicable healthcare facility procedures.
Always consult the current BD Alaris™ product labeling, Instructions for Use, and facility protocols before clinical use.
Specifications
- SterilitySterile
- Single PatientYes
- Autoclave ReadyNo