MQ Healthcare Distributor
0
0
All Products / Medical Supplies / IV Administration / Catheter & PICC Lines /
BD Insyte Autoguard BC Peripheral IV Catheters with Blood Control, Straight Hub – BX/50EA
/
BD Insyte Autoguard BC Peripheral IV Catheters with Blood Control, Straight Hub – BX/50EA
BD Insyte Autoguard BC Peripheral IV Catheters with Blood Control, Straight Hub – BX/50EA
BD Insyte Autoguard BC Peripheral IV Catheters with Blood Control, Straight Hub – BX/50EA
BD Insyte™ Autoguard™

BD Insyte Autoguard BC Peripheral IV Catheters with Blood Control, Straight Hub – BX/50EA

Sterile, disposable peripheral IV catheters featuring blood-control technology, a straight color-coded hub, BD Vialon biomaterial, and push-button needle shielding. Available in multiple gauge and length combinations, 50 catheters per box.
Non-returnable
$180.00
Gauge:
Choose Gauge
Length:
Choose Length
PKG:
Choose PKG
Customize
View Details
Share:

BD Insyte Autoguard BC Peripheral IV Catheters with Blood Control, Straight Hub – BX/50EA are designed for peripheral vascular access with integrated blood-control and push-button safety technologies. The blood-control valve helps restrict blood flow from the catheter hub until the initial connection is made, while the shielding mechanism fully encapsulates the needle after activation.

The radiopaque BD Vialon catheter material is paired with a notched stainless-steel needle and color-coded straight hub. Available configurations range from 24G to 16G, allowing the appropriate gauge and catheter length to be selected for the intended clinical procedure.

Key Features

Blood-Control TechnologyPush-Button SafetyStraight Hub
Restricts blood flow until the initial luer connection is madeActivates needle shielding with the push of a buttonCompact, non-winged configuration
BD Vialon BiomaterialBD Instaflash NeedleColor-Coded Gauges
Polyurethane catheter material designed for peripheral IV accessNotched needle supports vessel-entry visualizationHub color corresponds with catheter gauge
Sterile and DisposableRadiopaque CatheterMultiple Configurations
Individually packaged for single useSupports visualization under X-rayNine gauge and length combinations

Specifications

AttributeDetailsAttributeDetails
BrandInsyte Autoguard BCManufacturerBD
MPNVaries by VariantApplicationPeripheral IV catheter
Hub TypeStraight hubBlood ControlYes
Safety ActivationPush buttonSafety FeatureNeedle shielding
Catheter MaterialBD Vialon polyurethane biomaterialNeedle MaterialStainless steel
Needle PointNotchedVessel Entry ConfirmationBD Instaflash
Number of PortsWithout portPort TypeWithout port
SterilitySterileUsageDisposable / Single use
X-Ray CompatibilityRadiopaqueHub MaterialPlastic
Available Gauges24G, 22G, 20G, 18G, 16GAvailable Lengths3/4, 1, 1.16, 1.77 and 1.88 inches
Product PackagingCS/4BX/50EAMinimum Selling UnitBX/50EA
Catheters per Box50Catheters per Case200
Country of OriginUnited StatesUNSPSC42221512
BAA CompliantYesTAA CompliantYes

Variant Options

Primary Option: Gauge
Secondary Option: Catheter Length

Variant-to-MPN Mapping

GaugeLengthMPNHub ColorFlow RatePressure RatingPackaging
24G3/4 in.382512Yellow20 mL/minNot pressure ratedBX/50EA
22G1 in.382523Blue37 mL/min300 psiBX/50EA
20G1 in.382533Pink63 mL/min300 psiBX/50EA
20G1.16 in.382534Pink61 mL/min300 psiBX/50EA
20G1.88 in.382537Pink54 mL/min300 psiBX/50EA
18G1.16 in.382544Green95 mL/min300 psiBX/50EA
18G1.88 in.382547Green87 mL/min300 psiBX/50EA
16G1.16 in.382554Gray193 mL/minNot pressure ratedBX/50EA
16G1.77 in.382557Gray185 mL/minNot pressure ratedBX/50EA

Warnings

Trained Personnel OnlySingle-Use DeviceSterile Package Integrity
Use only by personnel trained in peripheral IV insertionDo not reuse or attempt to resterilizeDo not use if the individual package is opened, damaged, or compromised
Sharps SafetyCorrect Variant SelectionPressure Limitations
Activate the safety mechanism and dispose of the needle immediately after useSelect the gauge and length appropriate for the patient and procedureUse only pressure-rated variants for procedures requiring pressurized infusion
Inspect the DeviceFollow Clinical ProtocolDisposal
Do not use a bent, damaged, or defective catheter or needleFollow applicable vascular-access, infection-control, and site-monitoring proceduresDispose of used devices in an approved sharps container
Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.