ClearScan ECG Monitoring Electrodes 1-1/2 in Snap Wet Gel Radiolucent / MR Conditional – PK/60EA are designed for adult ECG monitoring during Cath Lab, X-ray, and other imaging procedures. The radiolucent construction and carbon-filled snap connector help reduce interference with the imaging field.
Each teardrop-shaped electrode features polyethylene foam backing, conductive wet gel, an Ag/AgCl sensor, and medical-grade adhesive. The resealable pouch contains 60 disposable electrodes intended for monitoring periods of up to 24 hours.
Key Features
| Radiolucent Construction | MR Conditional | Carbon-Filled Snap |
|---|
| Designed to reduce obstruction during imaging | Suitable only under specified MR conditions | Helps minimize interference with nuclear imaging systems |
| Conductive Wet Gel | Flexible Foam Backing | Resealable Pouch |
|---|
| Supports consistent ECG signal transmission | Conforms to the patient’s skin | Helps protect unused electrodes between procedures |
Specifications
| Attribute | Details | Attribute | Details |
|---|
| Brand | ClearScan | Manufacturer | Nissha Medical Technologies |
| MPN | A10004-60 | Product Type | ECG monitoring electrode |
| Patient Type | Adult | Usage | Disposable |
| Connection Type | Snap connector | Sensor | Ag/AgCl |
| Gel Type | Conductive wet gel | Backing Material | Polyethylene foam |
| Shape | Teardrop | Electrode Size | 1-1/2 in / 38.1 mm |
| Securing Method | Medical-grade adhesive | Adhesive Strength | Regular |
| Imaging Compatibility | Radiolucent / MR Conditional | X-Ray Translucent | Yes |
| Monitoring Duration | Up to 24 hours | Repositionable | No |
| Latex Indicator | Latex-free | Pouch Type | Resealable |
| Product Packaging | CS/10PK/60EA | Minimum Selling Unit | PK/60EA |
| Electrodes per Pack | 60 | Electrodes per Case | 600 |
| Shelf Life | 18 months | Sterility | Not Verified |
| HCPCS | A4556 | UNSPSC | 42181708 |
| BAA Compliant | No | TAA Compliant | No |
| Country of Origin | Not Verified | Integrated Abrader | No |
The product configuration, materials, dimensions, radiolucent construction, MR Conditional status, 24-hour use duration, latex-free status, and packaging quantities are supported by the current product specifications.
Warnings
| MR Conditional Product | Single-Use Electrode | Skin Preparation |
|---|
| Confirm and follow all specified MRI conditions before entering the MR environment | Do not reuse or apply to multiple patients | Prepare clean, dry skin according to facility protocol |
| Monitor Skin Condition | Package and Dating | Proper Placement |
|---|
| Inspect periodically for irritation, redness, or loss of adhesion | Verify pouch integrity and expiration dating before use | Apply and connect according to monitoring-equipment instructions |
| Not Repositionable | Removal | Disposal |
|---|
| Replace the electrode if repositioning is required | Remove carefully to reduce skin trauma | Dispose of used electrodes according to facility procedures |