HALYARD® FLUIDSHIELD™ 3 N95 Surgical Respirator, ASTM Level 3, Orange, Regular, BX/35 or CS/210
HALYARD® FLUIDSHIELD™ 3 N95 Particulate Respirators and Surgical Masks feature NIOSH-approved N95 filtration, ASTM Level 3 fluid protection at 160 mmHg, a breathable duckbill design, soft inner lining, adjustable nose wire, and dual elastic headbands. FDA-cleared for medical use, orange, non-sterile, and regular size. Available by Box (35 respirators) or Case (6 boxes / 210 respirators).
Customize
Product Details
The HALYARD® FLUIDSHIELD™ 3 N95 Particulate Respirator and Surgical Mask (MPN 46727) from O&M Halyard is designed for professional healthcare environments where both respiratory and fluid barrier protection are required. This NIOSH-approved N95 respirator combines particulate filtration performance with ASTM Level 3 fluid resistance for appropriate clinical applications.
The distinctive orange duckbill, pouch-style design provides a spacious breathing chamber while supporting comfortable wear. Its four-layer construction includes a soft SO SOFT™ inner lining, helping reduce discomfort during extended professional use. The respirator folds flat for convenient storage and handling.
Dual polyurethane elastic headbands are bonded rather than stapled, while a malleable, adjustable nose wire helps customize the fit. These features support proper positioning and facial sealing when the respirator is appropriately selected, fit-tested, and worn.
The FLUIDSHIELD™ 3 N95 respirator provides a minimum 95% filtration efficiency under NIOSH N95 requirements. Manufacturer technical testing also reports particulate filtration efficiency of at least 99% at 0.1 microns and bacterial filtration efficiency of at least 99%. Its fluid barrier performance is rated at 160 mmHg, corresponding to ASTM Level 3 protection.
This model is orange, non-sterile, regular adult size, and intended for single use.
Ordering & Packaging: Available by Box (BX/35EA) or Case (CS/6BX/35EA). Each case contains six manufacturer boxes of 35 respirators, totaling 210 disposable surgical N95 respirators. Individual respirators are not sold separately.
Key Features
| Feature | Detail | Feature | Detail |
|---|---|---|---|
| Respirator Classification | NIOSH N95 | Protection Level | ASTM Level 3 |
| NIOSH Approval | TC-84A-7521 | Fluid Resistance | 160 mmHg |
| Respirator Design | Duckbill / Pouch-Style | Fabric Construction | Four-Layer |
| Manufacturer-Reported PFE | ≥99% at 0.1 µm | Manufacturer-Reported BFE | ≥99% |
| Inner Lining | SO SOFT™ | Headband Style | Dual Polyurethane Elastic |
| Nose Adjustment | Malleable Nose Wire | Strap Attachment | Bonded, Not Stapled |
| Product Color | Orange | Size | Regular / One Size Fits Most |
| Sterility | Non-Sterile | Intended Use | Disposable / Single Use |
| Storage Design | Flat-Fold | Ordering Options | Box or Case |
Specifications
| Specification | Detail | Specification | Detail |
|---|---|---|---|
| Brand | HALYARD® FLUIDSHIELD™ | Manufacturer | O&M Halyard, Inc. |
| MPN | 46727 | McKesson Item # | 286249 |
| Product Type | N95 Particulate Respirator / Surgical Mask | Respirator Classification | N95 |
| NIOSH Approval | TC-84A-7521 | Protection Level | ASTM Level 3 |
| Fluid Resistance | 160 mmHg | Respirator Design | Duckbill |
| Construction | Four-Layer Fabric | Color | Orange |
| Inner Lining | SO SOFT™ | Headband Material | Polyurethane |
| Headband Attachment | Bonded | Nose Adjustment | Adjustable Nose Wire |
| Size | Regular / One Size Fits Most | Intended User | Adult |
| Sterility | Non-Sterile | Intended Use | Single Use |
| FDA Clearance | K233022 | FDA Primary Device Identifier | 20680651467274 |
| Box Configuration | BX/35EA | Case Configuration | CS/6BX/35EA |
| Respirators per Box | 35 | Respirators per Case | 210 |
| Ordering Units | BX, CS | HCPCS | A4928 |
| UNSPSC | 42131713 | BAA Compliant | No |
| TAA Compliant | Yes | Exhalation Valve | None |
Warnings
Intended for professional use in accordance with HALYARD instructions and applicable respiratory-protection requirements.
Respirators must be properly selected, fitted, and worn to provide the intended protection.
When required for occupational use, comply with OSHA 29 CFR 1910.134, including medical evaluation, fit testing, and training.
A secure facial seal is essential. Facial hair or other conditions that interfere with the seal may reduce protection.
N95 filtration is intended for certain airborne particulates. The respirator does not protect against gases, vapors, or oxygen-deficient atmospheres.
Inspect the respirator, nose wire, and elastic headbands before use. Do not use damaged, contaminated, or expired products.
Non-sterile, single-use product. Do not wash, modify, or reuse.
Replace the respirator if it becomes damaged, soiled, contaminated, or difficult to breathe through.
Follow manufacturer instructions for donning, seal checking, use limitations, removal, and disposal.
Store according to manufacturer specifications and observe the expiration date printed on the original packaging.
Misuse may result in illness or death.