McKesson Conventional Laryngoscope Handle, Medium Standard, LED, Knurled Grip, 2 C Battery Powered – Each
McKesson Conventional Laryngoscope Handle (4065MM) is a reusable, medium standard airway management handle designed for professional use with compatible laryngoscope blades. Constructed from satin chrome-plated brass, it features a knurled finish for a secure grip and a battery-operated LED light source.
The handle operates using two C-size batteries (not included) and is designed for use with compatible laryngoscope components conforming to applicable ASTM F965 or ISO 7376 standards.
Not made with natural rubber latex.
Ordering: Sold by Each Only (EA/1). Each purchase includes one medium standard laryngoscope handle. Batteries and laryngoscope blades are not included. Minimum selling/purchasing unit: Each.
Customize
Product Details
McKesson Conventional Medium Standard Laryngoscope Handle is a reusable medical device designed to support professional airway management and laryngoscopic examination procedures. The medium standard configuration provides a traditional hand-held format for use with compatible laryngoscope blades.
The handle features durable satin chrome-plated brass construction with a textured knurled finish that supports a secure grip during airway procedures. Its battery-operated design uses two C-size batteries, which are not included with the handle.
The product is listed with an LED light source and compatibility with green-coded laryngoscope systems. McKesson and distributor specifications also reference compatibility with major laryngoscope brands conforming to ASTM F965 or ISO 7376. Healthcare professionals should confirm the specific blade and illumination system compatibility before clinical use.
Suitable for hospitals, emergency departments, anesthesia departments, surgical facilities, clinics, and emergency preparedness equipment, this reusable handle supports routine professional airway equipment management. Cleaning, disinfection, inspection, and maintenance should follow the manufacturer's current instructions.
Ordering & Packaging: Sold by Each Only (EA/1). Each unit contains one McKesson Conventional Medium Standard Laryngoscope Handle, MPN 4065MM. Two C-size batteries are required for operation but are not included. Laryngoscope blades are sold separately. Minimum ordering unit: 1 Each.
Key Features
| Feature | Detail | Feature | Detail |
|---|---|---|---|
| Device Type | Laryngoscope Handle | Style | Conventional |
| Handle Size | Medium Standard | Light Source | LED |
| Power Source | Battery Operated | Battery Size | 2 C Batteries |
| Batteries Included | No | Handle Material | Chrome-Plated Brass |
| Finish | Satin / Knurled | Grip | Textured |
| Head Compatibility | Green-Coded Systems, Per Product Listing | Standards Referenced | ASTM F965 / ISO 7376 |
| Natural Rubber Latex | Not Made With | Usage | Reusable |
| Sterility | Nonsterile | Clinical Application | Airway Management |
| Packaging | EA/1 | Minimum Unit | EA |
Specifications
| Specification | Detail | Specification | Detail |
|---|---|---|---|
| Brand | McKesson | Manufacturer | McKesson Medical-Surgical |
| MPN | 4065MM | McKesson Item # | 1089420 |
| Product Type | Laryngoscope Handle | Handle Size | Medium Standard |
| Style | Conventional | Handle Finish | Knurled |
| Material | Satin Chrome-Plated Brass | Light Source Listed | LED |
| Power Source | Battery Operated | Battery Requirement | 2 C Batteries |
| Batteries Supplied | No | Laryngoscope Blade Included | No |
| Head Compatibility | Green-Coded Systems, Per Distributor | Referenced Standards | ASTM F965 / ISO 7376 |
| Sterility | Nonsterile | Reusability | Reusable |
| Natural Rubber Latex | Not Made With | Country of Origin | Pakistan |
| FDA Device Class | Class I | FDA Product Code | CCW |
| FDA Primary DI | 00612479232792 | UNSPSC | 42272018 |
| Selling Packaging | EA/1 | Minimum Selling Unit | Each |
| Available Ordering Units | EA Only | Application | Airway Equipment |
Warnings
FOR PROFESSIONAL MEDICAL USE — AIRWAY MANAGEMENT DEVICE.
Intended for use by appropriately trained healthcare professionals.
Confirm compatibility with the selected laryngoscope blade, illumination system, and clinical equipment before use.
Do not assume that conventional and fiber-optic laryngoscope components are interchangeable.
Two C-size batteries are required for operation and are not included.
Verify proper battery installation and functionality before clinical use.
Inspect the handle, electrical contacts, connection mechanism, grip, and light operation before each use.
Do not use a device that is damaged, corroded, malfunctioning, or unable to maintain a secure connection with the blade.
Confirm adequate illumination before beginning an airway procedure.
Follow the manufacturer's Instructions for Use for cleaning, disinfection, reprocessing, and maintenance.
Do not immerse, autoclave, or process the handle by a method unless specifically permitted by the manufacturer.
Replace batteries and maintain the equipment according to the manufacturer's instructions and facility protocols.
Do not assume MRI compatibility without specific manufacturer documentation.
Refer to the current McKesson Instructions for Use and applicable institutional airway management protocols.