Millennium Surgical Weitlaner Retractor, 4", Sharp 2×3 Prongs, 11 mm Depth × 15 mm Width – Each
Millennium Surgical Weitlaner Retractor (1-608) is a reusable, self-retaining surgical retractor with an overall length of 4 inches and a sharp 2×3 prong configuration. The working end features prongs measuring 11 mm deep and 15 mm wide, designed to maintain controlled exposure of tissue during appropriate surgical procedures.
Its compact configuration and adjustable retraction mechanism support access to smaller surgical fields where stable tissue separation is required.
Ordering: Sold by Each Only (EA/1). Each unit contains one Weitlaner Retractor. Minimum selling/purchasing unit: Each.
Customize
Product Details
Millennium Surgical Weitlaner Retractor is a reusable surgical instrument designed to provide self-retaining tissue retraction during operative procedures. Measuring 4 inches in overall length, the instrument features a compact design with opposing sharp prongs arranged in a 2×3 configuration.
The working end measures approximately 11 mm in depth and 15 mm in width, allowing controlled separation and exposure of tissue in appropriately sized surgical fields. Its self-retaining mechanism helps maintain the selected opening without continuous manual assistance.
The Weitlaner design is commonly used in general surgery, orthopedic procedures, and other surgical specialties where stable exposure of superficial or relatively small operative areas is needed. The sharp prongs are intended for secure tissue engagement when clinically appropriate.
This reusable instrument is supplied nonsterile and requires appropriate cleaning, inspection, and validated sterilization before clinical use. Follow the manufacturer's current reprocessing instructions and institutional instrument-care protocols.
Ordering & Packaging: Sold by Each Only (EA/1). Each purchase contains one Millennium Surgical Weitlaner Retractor, MPN 1-608. Minimum ordering unit: 1 Each.
Key Features
| Feature | Detail | Feature | Detail |
|---|---|---|---|
| Instrument Type | Weitlaner Retractor | Design | Self-Retaining |
| Overall Length | 4 Inches | Prong Configuration | 2 × 3 |
| Prong Style | Sharp | Prong Depth | 11 mm |
| Working Width | 15 mm | Retraction Control | Adjustable |
| Surgical Application | Tissue Retraction | Instrument Usage | Reusable |
| Sterility on Delivery | Nonsterile | Sterilization | Required Before Use |
| Device Classification | Prescription Use | Packaging | EA/1 |
| Ordering Units | Each Only | Minimum Unit | EA |
Specifications
| Specification | Detail | Specification | Detail |
|---|---|---|---|
| Brand | Millennium | Product Line | Millennium Surgical |
| FDA Labeler | Avalign Technologies, Inc. | MPN | 1-608 |
| Product Type | Surgical Retractor | Pattern | Weitlaner |
| Overall Length | 4 Inches | Overall Length (Metric) | Approx. 10.2 cm |
| Prong Configuration | 2 × 3 | Prong Style | Sharp |
| Prong Depth | 11 mm | Prong Width | 15 mm |
| Retraction Type | Self-Retaining | Usage | Reusable |
| Sterility | Nonsterile | Sterilization Before Use | Required |
| Sterilization Method | Steam, Per Manufacturer Instructions | FDA Product Code | GAD |
| FDA Primary DI | 00190776167295 | Prescription Use | Rx |
| Selling Packaging | EA/1 | Minimum Selling Unit | Each |
| Available Ordering Units | EA Only | Primary Application | Surgical Tissue Retraction |
Warnings
PRESCRIPTION USE (Rx) — FOR PROFESSIONAL SURGICAL USE.
Intended for use by appropriately trained healthcare professionals.
Supplied nonsterile. Clean and sterilize according to the manufacturer's validated instructions before clinical use.
Inspect the instrument, sharp prongs, and retraction mechanism before each use.
Do not use if the instrument shows damage, corrosion, deformation, misalignment, or impaired mechanical operation.
Sharp prongs may cause tissue injury if used incorrectly. Apply only the retraction necessary for the procedure.
Avoid excessive tissue traction or prolonged pressure.
Position the instrument carefully to prevent unintended contact with delicate structures.
Follow appropriate surgical and infection-control procedures throughout use.
After use, clean, inspect, and reprocess the instrument according to the manufacturer's current Instructions for Use.
Confirm compatibility with the selected sterilization process before reprocessing.
Do not assume MRI compatibility without device-specific labeling or manufacturer documentation.
Refer to the current Millennium Surgical/Avalign Technologies Instructions for Use for complete handling, cleaning, sterilization, and maintenance requirements.